Flexible Impeller Pumps RF c/w Cart
Operating principle
Due to the eccentric shape of the pump housing, a vacuum is created in the suction side that enlarges the volume between the blades and this causes the product suction.
The rotor is spinning and the product is carried from the suction side to that of delivery. Due to the eccentric shape of the pump housing, in the discharge side the blades bend, reducing the volume between them and causing the discharge of the product.
Design and features
Bare shaft or close-coupled construction.
Reversible and self-priming pump.
Machined investment casting casing.
Double flat drive of the impeller.
External single mechanical seal.
Easy maintenance.
Inoxpa RF Pumps need OVERSIZED Digital VFD to enable forward & reverse rotations.